| A | B |
| 100 | Definitions |
| 110 | Installation Requirements |
| 200 | Grounded Conductor |
| Grounded Conductor is also called the: | Neutral |
| 210 | Branch Circuits |
| 215 | Feeders |
| 220 | Branch Circuit Calculations |
| 225 | Outside Branch Circuits |
| 230 | Services |
| 240 | Overcurrent Protection |
| 250 | Grounding & Bonding |
| 280 | Surge Arrestors |
| 285 | TVSS (Transient Voltage Surge Arrestors) |
| Working Spaces is found in what ARTICLE? | 110 |
| "Exposed live parts" are found in tables | 110.34(A) &(E) |
| Fuses are found in ARTICLE: | 240 |
| GFCI & AFCI are BRANCH circuit protectors and are found in article: | 210 |
| Anything to do with Manholes and Manhole covers are found in: | 110, Part V |
| Mounting & Cooling of equipment is found in article: | 110 |
| The High-Leg color is found in article: | 110 |
| Flash Protection is found in | 110 |
| ID of Disconnecting Means | 110 |
| Current Transformers | 110. |
| Entrance and Access to Working Space | 110.34 |
| Fire Resistivity of Electrical Vaults | 110.31 |
| Tunnels OVER 600 Volts | 110.51-59 |
| The Use and ID of the Grounded Conductor (Neutral) | 200 |
| Branch Circuit Ratings are found in: | 210 |
| Required number of outlets is found in: | 210 |
| Heating,A/C and Refrigeration Equipment Outlets are found in: | 210 |
| Lighting OUTLETS Required | 210 |
| Show window OUTLETS | 210 |
| Feeders with a common neutral | 215 |
| Feeder Conductor Grounding Means | 215 |
| Branch Circuit Load calculations | 220 |
| Lighting loads for special occupancies | Table 220.12 |
| Feeder and Service Load Calculations | 220 |
| Feeder & Service Loads for general lighting | 220 |
| Show window lighting | 220 |
| Lighting load demand factors | Table 220.42 |
| Demand Factors for Non-dwelling Receptacles | Table 220.44 |
| Electric Clothes Dryers | Table 220.54 |
| Small Appliance & Laundry loads | 220 |
| Appliance loads | 220 |
| Kitchen eqipment | 220 |
| Demand Factor for household Electric Ranges | 220 |
| Optional Feeder and Service Load Calculations | 220 |
| Multifamily Dwelling Circuits, Feeders and Service Calculations | 220 |
| Farm Load Calculations for Circuit, Feeder, & Service Calculations | 220 |
| Outside Branch Circuits & Feeders | 225 |
| Attachments to building outside | 225 |
| Lighting equipment installed outdoors | 225 |
| Conductor size & support for outside type wiring | 225 |
| Supports over building | 225 |
| Masts & Supports on buildings | 225 |
| Circuit exits and entrances | 225 |
| Clearance from the ground for wiring outdoors | 225 |
| Mechanical Protection of conductors outdoors | 225 |
| More than one building or structure - Disconnecting means | 225 |
| Grouping of Disconnects on exterior | 225 Part II |
| Vegetation as support | 225 Part I |
| Maximum number of Disconnects | 225 Part II |
| Access to Occupants | 225 |
| Isolating switches for outside and more than one building | 225 |
| Clearances over Roadways, Walkways, Rails, Water and Open Land | Table 225.60 |
| Clearances over BUILDINGS and other structures | Table 225.61 |
| Services | 230 |
| Overhead Service-Drop Conductors | 230 Part II |
| Underground Service-Laterals Conductors | 230 Part III |
| Service Entrance Conductors | 230 Part IV |
| Service Equipment | 230 Part V |
| Service Equipment - Disconnects | 230 VI |
| Service Equipment - Overcurrent Protection | 230 Part VII |
| Service EXCEEDING 600 Volts | 230 Part VIII |
| Overcurrent Protection | 240 |
| Overcurrent Protection-General | 240 Part I |
| Overcurrent Protection-Locations: Underground Conductor, in circuit, grounded conductor (neutral), Size | 240 Part II |
| Overcurrent Protection-Enclosures | 240 Part III |
| Overcurrent Protection-Disconnecting and Guarding | 240 Part IV |
| Overcurrent Protection-Plug Fuses, Fuseholders & Adapters | 240 Part V |
| Overcurrent Protection-Cartidge Fuses and Fuse holders | 240 Part VI |
| Overcurrent Protection-Circuit Breakers | 240 Part VII |
| Overcurrent Protection-Industrial | 240 Part VIII |
| Overcurrent Protection-Over 600 Volts | 240 Part IX |
| Grounding & Bonding | 250 |
| Grounding & Bonding-General Requirements | 250 Part I |
| Grounding & Bonding Table for things specifically from A-X | TABLE 250.3 |
| Grounding & Bonding- System Grounding | 250 Part II |
| Grounding & Bonding-Electrode | 250 Part III |
| Grounding & Bonding- Enclosures Raceways, and Service Cable Grounding | 250 Part IV |
| Grounding & Bonding-Bonding Loosely Jointed metal, Hazardous,Jumpers,Lightning Protection | 250 Part V |
| Grounding & Bonding-EQUIPMENT Grounding | 250 Part VI |
| Grounding & Bonding- METHODS of Equipment Grounding | 250 Part VII |
| Grounding & Bonding-DC Current Systems | 250 Part VIII |
| Grounding & Bonding- Instruments, Meters, and Relays | 250 Part IX |
| Grounding & Bonding-1000 Volts | 250 Part X |
| Surge Arrestors | 280 |
| Surge Arrestors-Installation | 280 Part II |
| Surge Arrestors- Connecting | 280 Part III |
| TVSS- Transient Voltage Surge Suppressor | 285 |
| TVSS- Transient Voltage Surge Suppressor-Installation | 285 Part II |
| TVSS- Transient Voltage Surge Suppressor-Connecting | 285 Part III |