AB
100Definitions
110Installation Requirements
200Grounded Conductor
Grounded Conductor is also called the:Neutral
210Branch Circuits
215Feeders
220Branch Circuit Calculations
225Outside Branch Circuits
230Services
240Overcurrent Protection
250Grounding & Bonding
280Surge Arrestors
285TVSS (Transient Voltage Surge Arrestors)
Working Spaces is found in what ARTICLE?110
"Exposed live parts" are found in tables110.34(A) &(E)
Fuses are found in ARTICLE:240
GFCI & AFCI are BRANCH circuit protectors and are found in article:210
Anything to do with Manholes and Manhole covers are found in:110, Part V
Mounting & Cooling of equipment is found in article:110
The High-Leg color is found in article:110
Flash Protection is found in110
ID of Disconnecting Means110
Current Transformers110.
Entrance and Access to Working Space110.34
Fire Resistivity of Electrical Vaults110.31
Tunnels OVER 600 Volts110.51-59
The Use and ID of the Grounded Conductor (Neutral)200
Branch Circuit Ratings are found in:210
Required number of outlets is found in:210
Heating,A/C and Refrigeration Equipment Outlets are found in:210
Lighting OUTLETS Required210
Show window OUTLETS210
Feeders with a common neutral215
Feeder Conductor Grounding Means215
Branch Circuit Load calculations220
Lighting loads for special occupanciesTable 220.12
Feeder and Service Load Calculations220
Feeder & Service Loads for general lighting220
Show window lighting220
Lighting load demand factorsTable 220.42
Demand Factors for Non-dwelling ReceptaclesTable 220.44
Electric Clothes DryersTable 220.54
Small Appliance & Laundry loads220
Appliance loads220
Kitchen eqipment220
Demand Factor for household Electric Ranges220
Optional Feeder and Service Load Calculations220
Multifamily Dwelling Circuits, Feeders and Service Calculations220
Farm Load Calculations for Circuit, Feeder, & Service Calculations220
Outside Branch Circuits & Feeders225
Attachments to building outside225
Lighting equipment installed outdoors225
Conductor size & support for outside type wiring225
Supports over building225
Masts & Supports on buildings225
Circuit exits and entrances225
Clearance from the ground for wiring outdoors225
Mechanical Protection of conductors outdoors225
More than one building or structure - Disconnecting means225
Grouping of Disconnects on exterior225 Part II
Vegetation as support225 Part I
Maximum number of Disconnects225 Part II
Access to Occupants225
Isolating switches for outside and more than one building225
Clearances over Roadways, Walkways, Rails, Water and Open LandTable 225.60
Clearances over BUILDINGS and other structuresTable 225.61
Services230
Overhead Service-Drop Conductors230 Part II
Underground Service-Laterals Conductors230 Part III
Service Entrance Conductors230 Part IV
Service Equipment230 Part V
Service Equipment - Disconnects230 VI
Service Equipment - Overcurrent Protection230 Part VII
Service EXCEEDING 600 Volts230 Part VIII
Overcurrent Protection240
Overcurrent Protection-General240 Part I
Overcurrent Protection-Locations: Underground Conductor, in circuit, grounded conductor (neutral), Size240 Part II
Overcurrent Protection-Enclosures240 Part III
Overcurrent Protection-Disconnecting and Guarding240 Part IV
Overcurrent Protection-Plug Fuses, Fuseholders & Adapters240 Part V
Overcurrent Protection-Cartidge Fuses and Fuse holders240 Part VI
Overcurrent Protection-Circuit Breakers240 Part VII
Overcurrent Protection-Industrial240 Part VIII
Overcurrent Protection-Over 600 Volts240 Part IX
Grounding & Bonding250
Grounding & Bonding-General Requirements250 Part I
Grounding & Bonding Table for things specifically from A-XTABLE 250.3
Grounding & Bonding- System Grounding250 Part II
Grounding & Bonding-Electrode250 Part III
Grounding & Bonding- Enclosures Raceways, and Service Cable Grounding250 Part IV
Grounding & Bonding-Bonding Loosely Jointed metal, Hazardous,Jumpers,Lightning Protection250 Part V
Grounding & Bonding-EQUIPMENT Grounding250 Part VI
Grounding & Bonding- METHODS of Equipment Grounding250 Part VII
Grounding & Bonding-DC Current Systems250 Part VIII
Grounding & Bonding- Instruments, Meters, and Relays250 Part IX
Grounding & Bonding-1000 Volts250 Part X
Surge Arrestors280
Surge Arrestors-Installation280 Part II
Surge Arrestors- Connecting280 Part III
TVSS- Transient Voltage Surge Suppressor285
TVSS- Transient Voltage Surge Suppressor-Installation285 Part II
TVSS- Transient Voltage Surge Suppressor-Connecting285 Part III