Unit 17. Motors

AB
A split-phase motor has a ____ winding and a ____ winding.start, run
A split-phase motor can use what three ways to energize and de-energize the start winding?potential relay, current relay, centrifugal switch
A current magnetic relay opens and closes its contacts based on the ____.current in the run winding
A permanent split capacitor (PSC) motor that is running and up to speed will have the ________ energized.start winding
A split-phase motor that has a current relay and a start capacitor is called a ____ motor.Capacitor Start, Induction Run (CSIR)
Do the start windings have more turns or fewer turns than the run windings?more
When a general duty split-phase motor reaches approximately 75% of its operating speed, the start winding is de-energized by a ____.centrifugal switch
Capacitors wired in series with the starting winding provide greater ____.starting torque
The shaded pole motor has little ____.starting torque
Three phase motors have only what kind of windings?run windings
A current magnetic relay opens and closes its contacts based on the ____.current in the run winding
A motor's speed is determined by ____.the number of motor poles
The positive-temperature-coefficient start device is a type of ____.thermistor
Does a permanent split-capacitor motor have a run capacitor only, a start capacitor only, or both run and start capacitors?run capacitor only
The heavier the load on an operating motor, the greater the amount of ____.slip
The microfarad rating of the start capacitor is always much _____ than that of the run capacitor.higher
Are the contacts in a current type starting relay normally open or closed?open