Electrical

AB
1. T/F The service size is determined by the amperage and voltage ratings of the serviceTrue
2. T/F The drip loop should be close to the roof surface as possible.False the bottom of a drip loop should be well above the roof 12 to 24 inches deepening on jurisdiction
/F A 200-amp service will have two 100-amp fuses in the service panelFalse Two 100-amp fuses indicate 100 amp service. You cannot add the two fuses together to determine a service size
4. T/F There can be up to 10 throws to disconnect all of the electricity in the houseFalse there can be up to 6
5. T/F Electrical wiring in a house is a direct current.. False it is an alternating current
6. T/F A 120- volt circuit uses black and red wireFalse 120- volt circuits use a black wire and a white wire; others use red and white
7. T/F All service entrance conductors must be in a conduit.False they may be in a conduit on the outside of the building or there maybe a special service entrance cable that does not require a conduit
8. T/F Load calculations are required as part of a home inspectionFalse
9. T/F The service box can be inside outside or in the garage.True
10. T/F You are allowed to ground the gas piping.False much of the gas underground piping is plastic, plastic is not a good conductor of electricity.
11. T/F Outlets should be as close to basins as possibleTrue
12. Which of the following is true about Electrical resistance?Increases with increasing diameter, decreases with increasing wire diameter, decreases with increasing wire length, is higher for copper than for aluminum.decreases with increasing wire diameter
13. Assuming copper, standard wire type and normal temperature rating, what is the typical conductor size in AWG for 200-A service in the United States?2/0
14. The power available in a typical 15-A, 120-V household circuit is¬¬¬____?1800 W
15. What is the frequency (cycles/second) of house-hold electricity?60Hz
16. A service box with a black wire, red wire, white wire, and two 200-A fuses indicates a ____?120/240-V, 200-A service
17. What would two wires entering the service weatherhead indicate to you?An older 120-V system
18. You notice rust in the service panel. Which of the following may be the cause? No drip loop, undersized conduit, damaged masthead, both a and c.both a and c
19. T/F The Best location for an outlet is immediately beside a basin in a bathroomTrue
20. T/F GIFI receptacles are accepted as an alternative for grounded under some circumstances.True
21. T/F A properly polarized circuit will result in the threaded collar of a lampTrue
22. T/F Three way switches control lights from two different locationstrue
23. T/F Overloading the neutral wire on a multiwire branch circuit is likely if the black and red wires are powered by the same bus.True
24. Aluminum wiring is used on which of the following, 12- gauge circuits, 8 gauge circuits, 10 gauge circuits, commercial applications only.8 gauge
25. Wires should not be run across the tops of ceiling joist in attics unless the attic height is less than __ inches.40