| A | B |
| 113.1 State the type and application of the SSTGs | 4 Delaval SSTGs, GJ condensing turbine type, KD speed reducing gear unit, 2500 kW, 450 V, 60 Hz, 4 kA, generates power for the ship |
| 113.2 State the location of the SSTG | Engine room portside |
| 113.3a State the rated capacity of the SSTG as it applies to: Amps | 4000 A |
| 113.3b State the rated capacity of the SSTG as it applies to: kW | 2500 kW |
| 113.3c State the rated capacity of the SSTG as it applies to: Volts | 450V |
| 113.3d State the rated capacity of the SSTG as it applies to: Cycles | 60 Hz |
| 113.4 Other SSTG facts | Operate off of 600lb main steam, convert ships steam in 2500kW AC for lighting and ship's power |