AB
Battery:Device that changes chem energy into elec energy.
Fixed Capacitor:2 conducting surfaces separated by an insulator that stores elect energy.
Conductor Connected: Wires suitable for carrying an electrical current is on.
Conductor Not Connected: Wires suitable for carrying an elect. current is off
Fuse:Device in the conductive path with a melting point coordinated to load current.
Ground:Conducting connection, which an electric circuit, the earth.
Inductor Air Coil: Wound wire creating a magnetic field which does not use iron to achieve inductance.
Fuse:Device in the conductive path with a melting point coordinated to load current.
Fusible Link:A short section of wire that melts to interrupt the circuit when current is exceeded.
Rectifier (Diode):A semiconductor device which allows current to flow through it in only one direction.
Shielded Cable:High voltage power cable enclosed in a non-magnetic conducting envelope.
Inductor Iron core:Coil of wire with a metallic or ferrite core that create a magnetic field when energized.
Lamp Incandescent:Produces light by heating filament. Higher temperatures produce more light.
Line Connection: Line to line connection used for high power appliances.
Motor Single Phase:Alternating devices needing a starting capacitor or switch .Used for small appliances.
Motor Three Phase: Device with 3 windings that runs on A.C. to magnetize the windings to turn the rotor.
Resistor Fixed:Used to reduce the flow of electric current. Value can not be changed.
Thermal Overload Coil:Device preventing an electric motor from drawing too much current and overheating.
Thermistor:resistors with a negative (NTC), or positive (PTC) resistance/temperature coefficient.
Bell Alarm:Switch with a circuit breaker actuated to closed condition in response to tripping of the circuit.
Horn Alarm: Switch with a circuit breaker actuated to closed condition in response to tripping of the circuit.
Thermocouple:Temperature sensor used to convert thermal potential difference into electrical.
Resistor Variable:Reduces the flow of elec current. Resistance track, end connections and a wiper which moves when the spindle turns.
Solenoid:A cylindrical spiral of conducting wire. Electric current creates turns = to a parallel circuits.
Transformer Air Core: Coils of wire wound on a form with no core.Transfers energy from by magnetic coupling.
Transformer Iron Core: Transfers energy at low frequencies with a core of low-reluctance magnetic material.
Voltmeter:A device used to measure the voltage drop.
Wattmeter: pair of fixed coils and a movable coil used to measure electrical power.
Connector-male:Mechanism used to unite two pieces of cable both physically and electrically.
Connector-female: Mechanism used to unite two pieces of cable both physically and electrically.
Engaged
4 conductor
Pressure.Vacuum Switch NO:Pressure changes ,opens/ closes one or more electrical switching elements.
Pressure.Vacuum Switch NC:Pressure changes ,opens/ closes one or more electrical switching elements.
Liquid Level Switch NO: Sense the level of liquid within a tank. The switch actuates a device.
Liquid Level Switch NC: Sense the level of liquid within a tank. The switch actuates a device.
Flow Switch NO:Pressure chansge generated by flow actuates an electrical switch.
Flow Switch NC:Pressure chansge generated by flow actuates an electrical switch.
Timed Contacts NC:Timing based techniques rely on adding sufficient delays to prevent bounce being detected
Timed Contacts NO:Timing based techniques rely on adding sufficient delays to prevent bounce being detected
Single Pole Throw Switch:Makes or breaks the connection of one conductor and controls one load from one location.
Double Pole Single Throw Switch:Makes or breaks the connection of two conductors of a single branch circuit.
Double Pole Double Throw Switch:A mechanical device used to open and close two circuits.
Temp Activated Switch NC: Upon the temperature changes, opens/closes electrical switching elements.
Temp Activated Switch NO: Upon the temperature changes, opens/closes electrical switching elements.
Three Position Switch
State where current flows until the plunger pin is actuated to open the electrical circuit.Normally Closed
State where current flows until the plunger pin is actuated to close the electrical circuiNormally Open